Check Files 2d uvpt
Revision as of 09:43, 28 October 2024 by Emilie Nielsen (talk | contribs) (→Attributes of _uvpt_check)
Introduction
This GIS file contains information about the cell sides (U and V points).
Attributes of _uvpt_check
General Attributes
Attribute Name | Attribute Description |
---|---|
n | Row number in the TUFLOW domain. |
m | Column number in the TUFLOW domain. |
Type | Zpt type (U or V). |
Init_Vel | Initial Velocity. |
Mannings_n (default) Chezy_Coeff Mannings_M |
Roughness coefficient. |
FLC | Additional form loss applied. |
WrF | Weir factor. |
FC_Depth_to_Lid (only if the model has flow constrictions) | For flow constrictions, the depth to the obvert. |
FC_BD_Factor (only if the model has flow constrictions) | For flow constrictions, the bridge deck factor. |
FC_Width_Factor (only if the model has flow constrictions) | For flow constrictions, the flow width factor. |
Domain_Index | The index of the model domain. This is the order with Start 2D Domain == <Domain Name> commands appears in the TCF control file. For a single domain model this will be 1. |
Attributes when using quadtree
Attribute Name | Attribute Description |
---|---|
qpc_id | The quadtree cell ID. |
Type | Zpt type (U or V). |
Init_Vel | Initial Velocity. |
Mannings_n (default) Chezy_Coeff Mannings_M |
Roughness coefficient. |
Features
The image below shows the _uvpt_check styled by the Manning's n value. Note if using depth varying varying roughness the Material ID attribute in the _grd_check file may be preferred.
Up |
---|
TUFLOW Check Files |