Revision as of 01:41, 2 November 2024 by ElizaCollison (talk | contribs) (Created page with "{{TUFLOW_Message |tuflow_message=WARNING 2920 - Some merge polygon vertex are outside quadtree sub-domain. Current nesting level = n |alt_msg=CHECK 2920 - Some merge polygon...")
TUFLOW Message
WARNING 2920 - Some merge polygon vertex are outside quadtree sub-domain. Current nesting level = n
Alternate Message
CHECK 2920 - Some merge polygon vertex are located inside quadtree cell(s) from different nesting level. Processing nesting level = n
Description
Issues can occur in the TIN process when 2d_zsh polygons intersect with multiple quadtree levels.
Suggestions
Check by reviewing the _zsh_zpt and DEM_Z check files that the appropriate topography modifications have been applied. If they haven't, create a TIN using QGIS or SMS and read the TIN into TUFLOW directly (using the 'Read TIN Zpts ==' command).