TUFLOW Message 5103

From Tuflow
Revision as of 12:17, 1 April 2025 by Emilie Nielsen (talk | contribs) (Created page with "{{TUFLOW_Message |tuflow_message=ERROR 5103 - Both receiving polygon == and pollutant == need to be specified in catchment hydraulic model block in the pollutant export config...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

TUFLOW Message
ERROR 5103 - Both receiving polygon == and pollutant == need to be specified in catchment hydraulic model block in the pollutant export configuration. Exiting.

Alternate Message
NA

Message Type
ERROR

Description
The TUFLOW CATCH simulation is in a pollutant export configuration, however the command "Receiving Polygon == " and/or "Pollutant == " have not been specified in the catchment hydraulic model block of the TUFLOW CATCH Control file (.tcc).

Suggestions
Both of the above commands must be specified in the catchment hydraulic model block when TUFLOW CATCH is in pollutant export configuration.
Refer to the TUFLOW CATCH Manual for more information.


Up
Go-up.png 5xxx Messages