ERROR 5124 - Treatment device specified without GIS layer. Exiting.

Alternate Message
NA

Message Type
ERROR

Description
A treatment device has been specified without a GIS intervention layer (2d_im). In the pollutant export model block of the TUFLOW CATCH Control file (.tcc), a treatment device has been specified via the command "Device == ", but no 2d_im layer has been defined (Read GIS Intervention == ).

Suggestions
Create a 2d_im GIS layer and use the "Read GIS Intervention == " command in the pollutant export model block of the .tcc to read in the file.