TUFLOW Message 5053

From Tuflow
Revision as of 15:07, 1 May 2025 by Emilie Nielsen (talk | contribs) (Created page with "{{TUFLOW_Message |tuflow_message=ERROR 5053 - Lateral boundary interval must be the same as or greater than the nodestring boundary interval. |alt_msg=NA |type=ERROR |mess...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

TUFLOW Message
ERROR 5053 - Lateral boundary interval must be the same as or greater than the nodestring boundary interval.

Alternate Message
NA

Message Type
ERROR

Description
Lateral boundary interval (Catch BC Output Interval Lateral == ) must be equal to or greater than the nodestring boundary interval (Catch BC Output Interval Nodestring == ).

Suggestions
In the 'Global Commands' section of the TUFLOW CATCH Control file (.tcc), ensure the lateral boundary interval is equal to or greater than the nodestring boundary interval.


Up
Go-up.png 5xxx Messages