Difference between revisions of "Check Files 2d fcsh uvpt"

From Tuflow
Jump to navigation Jump to search
(Created page with "To be created")
 
 
Line 1: Line 1:
To be created
+
Contains information on the cell sides (U and V points) that have a flow constriction shape object applied.  This contains information on the processed elevations, blockages and form loss values applied at the cell side.
 +
<br>
 +
 
 +
'''Attributes of fcsh_uvpt'''<br>
 +
{| align="center" class="wikitable" width="75%"
 +
! style="background-color:#005581; font-weight:bold; color:white;"| Attribute Name
 +
! style="background-color:#005581; font-weight:bold; color:white;" width=75%| Attribute Description
 +
|-
 +
| FC_Type||The flow constriction type as described in the TUFLOW manual.
 +
|-
 +
| Z_Bed||The ground level of the z point.
 +
|-
 +
| Obvert_or_BC_H_or_FD_Depth|| This attribute is dependent on the FC type:<br>
 +
* For a blank flow or "BD" constriction type this is the structure obvert.  Above this elevation there is no additional flow area.
 +
* For a "BC" constriction type this is the height of the box culvert.
 +
* For a "FD" constriction type this is the depth of the object.
 +
|-
 +
| pBlockage||The percentage (%) blockage of below the deck level, above this the blockage is 100%.
 +
|-
 +
| FLC_below_Obvert||The '''F'''orm '''L'''oss '''C'''oefficient below the structure obvert.
 +
|-
 +
| FLC_above_Obvert||The '''F'''orm '''L'''oss '''C'''oefficient above the structure obvert.
 +
|-
 +
| BC_n_or_BD_n||For the "BC" or "BD" type constrictions this is the n attribute.
 +
|-
 +
| BC_Width||For a "BC" type this is the box culvert width.
 +
|-
 +
| Source||This is the source GIS layer which contains the flow constriction shape.
 +
|}

Latest revision as of 15:38, 14 December 2015

Contains information on the cell sides (U and V points) that have a flow constriction shape object applied. This contains information on the processed elevations, blockages and form loss values applied at the cell side.

Attributes of fcsh_uvpt

Attribute Name Attribute Description
FC_Type The flow constriction type as described in the TUFLOW manual.
Z_Bed The ground level of the z point.
Obvert_or_BC_H_or_FD_Depth This attribute is dependent on the FC type:
  • For a blank flow or "BD" constriction type this is the structure obvert. Above this elevation there is no additional flow area.
  • For a "BC" constriction type this is the height of the box culvert.
  • For a "FD" constriction type this is the depth of the object.
pBlockage The percentage (%) blockage of below the deck level, above this the blockage is 100%.
FLC_below_Obvert The Form Loss Coefficient below the structure obvert.
FLC_above_Obvert The Form Loss Coefficient above the structure obvert.
BC_n_or_BD_n For the "BC" or "BD" type constrictions this is the n attribute.
BC_Width For a "BC" type this is the box culvert width.
Source This is the source GIS layer which contains the flow constriction shape.