This GIS file contains information about the cell sides (U and V points). <br>
 +
<br>
 +
'''Attributes of uvpt_check'''<br>
 +
{| align="center" class="wikitable" width="75%"
 +
! style="background-color:#005581; font-weight:bold; color:white;"| Attribute Name
 +
! style="background-color:#005581; font-weight:bold; color:white;" width=75%| Attribute Description
 +
|-
 +
| n||Row number in the TUFLOW domain
 +
|-
 +
| m||Column number in the TUFLOW domain
 +
|-
 +
| Type||Zpt type (U or V)
 +
|-
 +
| Init_Vel||Initial Velocity
 +
|-
 +
| Mannings_n (default)<br>Chezy_Coeff<br>Mannings_M ||Roughness coefficient
 +
|-
 +
| FLC||Additional form loss applied
 +
|-
 +
| WrF||Weir factor.
 +
|-
 +
| FC_Depth_to_Lid (only if the model has flow constrictions)||For flow constrictions, the depth to the obvert.
 +
|-
 +
| FC_BD_Factor (only if the model has flow constrictions)||For flow constrictions, the bridge deck factor
 +
|-
 +
| FC_Width_Factor (only if the model has flow constrictions)||For flow constrictions, the flow width factor.
 +
|-
 +
| Domain_Index||The index of the model domain.  This is the order with <tt>Start 2D Domain == <Domain Name></tt> commands appears in the .tcf control file.  For a single domain model this will be 1.
 +
|}
 +
<br>
 +
The image below shows the uvpt styled by the Manning's n value.  Note if using depth varying varying roughness the Material ID attribute in the <u>[[Check_Files_2d_grd | _grd_check file]]</u> may be preferred.<br>
 +
[[File:Check Files uvpt n 01.jpg]]

Latest revision as of 09:17, 2 February 2016

This GIS file contains information about the cell sides (U and V points).

Attributes of uvpt_check

Attribute Name Attribute Description
n Row number in the TUFLOW domain
m Column number in the TUFLOW domain
Type Zpt type (U or V)
Init_Vel Initial Velocity
Mannings_n (default)
Chezy_Coeff
Mannings_M
Roughness coefficient
FLC Additional form loss applied
WrF Weir factor.
FC_Depth_to_Lid (only if the model has flow constrictions) For flow constrictions, the depth to the obvert.
FC_BD_Factor (only if the model has flow constrictions) For flow constrictions, the bridge deck factor
FC_Width_Factor (only if the model has flow constrictions) For flow constrictions, the flow width factor.
Domain_Index The index of the model domain. This is the order with Start 2D Domain == <Domain Name> commands appears in the .tcf control file. For a single domain model this will be 1.


The image below shows the uvpt styled by the Manning's n value. Note if using depth varying varying roughness the Material ID attribute in the _grd_check file may be preferred.
Check Files uvpt n 01.jpg