Difference between revisions of "TUFLOW Message 2206"

From Tuflow
Jump to navigation Jump to search
(Created page with '{{TUFLOW_Message |tuflow_message=???? |message_desc=Zpt has not been assigned an elevation value or the value exceeds 99998m. Use the Set Zpts == command in the .tgc file to ass...')
 
 
(4 intermediate revisions by 3 users not shown)
Line 1: Line 1:
 
{{TUFLOW_Message
 
{{TUFLOW_Message
|tuflow_message=????
+
|tuflow_message=ERROR 2206 - ZC value not initialised (exceeds 99998m)
|message_desc=Zpt has not been assigned an elevation value or the value exceeds 99998m.  Use the Set Zpts == command in the .tgc file to assign a global value.
+
|alt_msg=ERROR 2206 - ZU value not initialised (exceeds 99998m)<br>
|suggestions=????
+
ERROR 2206 - ZV value not initialised (exceeds 99998m)<br>
|discussion_page=* [[Talk:TUFLOW Message 2206|Discuss Message 2206]]
+
ERROR 2206 - ZH value not initialised (exceeds 99998m)<br>
|link3=''
+
|type=[[ERROR]]
|link4=''
+
|message_desc=Zpt has not been assigned an elevation value or the value exceeds 99998m.  All active model points should have an elevation assigned via one of;
|prelink=[[TUFLOW_Message_2205|Message 2205]]
+
gridded elevation data (Read Grid Zpts), TIN (Read TIN Zpts), TUFLOW topography modification layer (e.g. 2d_zsh, 2d_z), or via a default command (Set Zpt == <value>).
|nextlink=[[TUFLOW_Message_2234|Message 2234]]
+
|suggestions=To determine where the zpts with an assigned elevations occur, import the messages layer for the run ("<run_name>_messages.mif" for MapInfo users or "<run_name>_Messages_P.shp" for other GIS users).  Each location that an elevation or 99,998 or higher is encountered a message will be generated.  Check that these zpts have a valid elevation supplied and do not have any topography modifiers set a high elevation.
 +
 
 +
 
 +
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 +
 
 
}}
 
}}

Latest revision as of 14:05, 7 February 2023

TUFLOW Message
ERROR 2206 - ZC value not initialised (exceeds 99998m)

Alternate Message
ERROR 2206 - ZU value not initialised (exceeds 99998m)
ERROR 2206 - ZV value not initialised (exceeds 99998m)
ERROR 2206 - ZH value not initialised (exceeds 99998m)

Message Type
ERROR

Description
Zpt has not been assigned an elevation value or the value exceeds 99998m. All active model points should have an elevation assigned via one of; gridded elevation data (Read Grid Zpts), TIN (Read TIN Zpts), TUFLOW topography modification layer (e.g. 2d_zsh, 2d_z), or via a default command (Set Zpt == <value>).

Suggestions
To determine where the zpts with an assigned elevations occur, import the messages layer for the run ("<run_name>_messages.mif" for MapInfo users or "<run_name>_Messages_P.shp" for other GIS users). Each location that an elevation or 99,998 or higher is encountered a message will be generated. Check that these zpts have a valid elevation supplied and do not have any topography modifiers set a high elevation.


Up
Go-up.png 2xxx Messages