Difference between revisions of "TUFLOW Message 2541"

From Tuflow
Jump to navigation Jump to search
Line 1: Line 1:
 
{{TUFLOW_Message
 
{{TUFLOW_Message
|tuflow_message=CHECK 2541 - SX polygon selects no cells, centroid used.
+
|tuflow_message=ERROR 2541 - SX polygon selects no cells.
|alt_msg=NA
+
|alt_msg=CHECK 2541 - SX polygon selects no cells, centroid used.
 
|type=[[CHECK]]
 
|type=[[CHECK]]
|message_desc=No cell centre falls within SX polygon, centroid will be used to choose the cell as a connection between 1D and 2D.
+
|message_desc=No cell centre falls within SX polygon. If the message type is "CHECK", the SA polygon centroid still falls within the active model domain and the centroid will be used to choose the nearest cell as a connection between 1D and 2D. If the message type is "ERROR", the SA polygon centroid falls outside the model and the TUFLOW will exit with error.  
|suggestions=Review the SX polygon size and location.
+
|suggestions=Review the SX polygon size and check if it is located inside the active model domain.
 
|discussion_page=* [[Talk:TUFLOW Message 2541|Discuss Message 2541]]
 
|discussion_page=* [[Talk:TUFLOW Message 2541|Discuss Message 2541]]
 
|link3=''
 
|link3=''

Revision as of 13:46, 24 December 2020

TUFLOW Message
ERROR 2541 - SX polygon selects no cells.

Alternate Message
CHECK 2541 - SX polygon selects no cells, centroid used.

Message Type
CHECK

Description
No cell centre falls within SX polygon. If the message type is "CHECK", the SA polygon centroid still falls within the active model domain and the centroid will be used to choose the nearest cell as a connection between 1D and 2D. If the message type is "ERROR", the SA polygon centroid falls outside the model and the TUFLOW will exit with error.

Suggestions
Review the SX polygon size and check if it is located inside the active model domain.


Up
Go-up.png 2xxx Messages