ERROR 5044 - Unable to determine generation type, expecting "Method == " within line

Alternate Message
NA

Message Type
ERROR

Description
The pollutant generation type has not been defined with the other pollutant export properties.

Suggestions
In the TUFLOW CATCH control file (.tcc), ensure that in each material block (Material == <Material ID>), the pollutant generation type is defined within the pollutant export properties. For example:

Material == <Material ID>
<name>, Method==<pollutant generation type>, ...
End Material

For more information, refer to the TUFLOW CATCH Manual.