Content deleted Content added
|
|
|
'''Suggestions:'''
* Ensure storage locations that outputs are written to have ample free space. Depending on the infrastructure, reported free space may not be accurate, or performance of storage may substantially degrade as it nears being full.
* If the output drive does have more than enough space, insertInsert "pause" at the end of the batch file and remove any start "TUFLOW", -b and/or -t switch to keep the simulation console window open and send a snapshot of the console window and ,.tlf and .hpc.tlf to support@tuflow.com. Note: the simulation console window is one stating for example "TUFLOW Build: 2020-10-AB-iSP-w64" in the header's top left corner. If the only console window that stays open states "C:\\WINDOWS\system32\cmd.exe" that is the batch file console window which won't provide desired information. <u>[[Run_TUFLOW_From_a_Batch-file#Batch_file_for_Tutorial_Model_Module_1 | Simple batch file]]</u> should be used if loopingcurrent batch file doesn't keep the simulation console window open even with the suggested changes.<br>
<br>
|