*Pipe Failure control commands contained within the '<font color="blue"><tt>Define Pipe Failure Control</tt></font> <font color="red"><tt> ==</tt></font> <font color="black"><tt> PF01</tt></font>' logic block:
:*The piping failure is triggered when the water level at the upstream node of the 1d_nwk PF01 line is greater than 59.5m.
:*The piping failure takes 0.5 hours to reach it'sits full extent (defined by the width and height attributes in the 1d_nwk layer).
:*Once the piping failure reaches it'sits full extent, it takes 60 seconds to collapse.
:*The default shape of the piping failure is rectangular.